© May 2012 Littelfuse Protection Relays & Controls www.littelfuse.com/relayscontrols
Accessories
TERMINATIONS AND ADAPTERS
Product Features Accessory For
1N5339B
Termination Device
5 W axial-lead ground-check termination. Included with SE-105 and
SE-107.
SE-105
SE-107
SE-TA6-SM
Stud-Mount Termination
Assembly
50 W ground-check termination that is robust and compact for
submersible pumps. Wire lead simplifies installation.
(Replacement for 1N4553B)
SE-105
SE-107
SE-TA6
Termination Assembly
50 W ground-check termination with convenient mounting holes and
screw terminals.
SE-105
SE-107
SE-TA6A
(PGA-0T6A)
Termination Assembly
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-105
SE-107
SE-134C
SE-TA6A-WL
Termination Assembly
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-105
SE-107
SE-134C
SE-TA6ASF-WL
Small-Format Termination
Assembly with Wire Leads
Temperature compensated 12 W ground-check termination, ideal
for use in cable-coupler end caps and submersible pumps. Mounting
holes and wire leads.
SE-105
SE-107
SE-134C
SE-TA12A
Termination Assembly
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-135
SE-145
SE-TA12ASF-WL
Small-Format Termination
Assembly with Wire Leads
Temperature compensated 12 W ground-check termination, ideal
for use in cable-coupler end caps and submersible pumps. Mounting
holes and wire leads.
SE-135
SE-145
SE-TA12A-WL
Termination Assembly
Temperature compensated 50 W ground-check termination with
convenient mounting holes and screw terminals.
SE-135
SE-145
SE-TA12A
SE-TA12B
Termination Assemblies
Used together to allow an SE-134C to monitor a splitter box and two
cables.
SE-134C
PPI-600V
Parallel Path Isolator
Parallel ground-path rejection for ground-check monitors. Eliminates
intermachine arcing and prevents stray DC currents from flowing in
a monitored ground wire.
SE-105 SE-107
SE-134C SE-135
RK-13
Relay Interface Module
Separate ground-fault and ground-check indication contacts for the
SE-105, and separate ground-fault and resistor-fault contacts for the
SE-325. Used to provide output to a PLC and operate standard pilot
lights. Complete with conformally coated circuit boards.
SE-105 SE-107
SE-325
SE-485-DIN
Industrial RS-485 to RS-232
Converter
Industrial network quality RS-485 to RS-233 serial converter.
DIN-rail mounted, 24 Vdc required.
MPS
FPS
SE-485-PP
Port-Powered Serial
Converter
Converts an RS-485 signal to an RS-232 signal. Used for set-point
programming and updating flash memory. 115.2 kbit/s maximum
transfer rate.
MPU-32 MPS
FPU-32 FPS
CA-945
Serial Connector Adapter Kit
Connects an RJ45 to a 9-pin serial connector. Includes 1.5 m cable
and plug-in adapter.
MPU-32
FPU-32
SE-ICUSB232
USB to RS-232 Converter
Connects a 9-pin serial cable to a USB port.
SE-330 CA-945
SE-330AU SE-330HV
SE-485-PP SE-485-DIN
TERMINATIONS AND ADAPTERS
Terminations, Adapters
Page view 0
1 2

Summary of Contents

Page 1 - TERMINATIONS AND ADAPTERS

© May 2012 Littelfuse Protection Relays & Controls www.littelfuse.com/relayscontrolsAccessoriesTERMINATIONS AND ADAPTERSProduct Features Acce

Page 2

© May 2012 Littelfuse Protection Relays & Controls www.littelfuse.com/relayscontrolsAccessoriesTERMINATIONS AND ADAPTERSProduct Features Acce

Comments to this Manuals

No comments