45
Revised: March 19, 2012
POLY-FUSE
®
Resettable PTCs
© 2012 Littelfuse, Inc
2016L Series
Surface Mount > 2016L Series
2016L Series
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/2016L.html for current information.
2016L Series
The 2016L Series PTC provides surface mount overcurrent
protection for low voltage (≤60V) applications where
resettable protection is desired.
Electrical Characteristics
Part Number Marking
I
hold
(A)
I
trip
(A)
V
max
(Vdc)
I
max
(A)
P
d
typ.
(W)
Maximum Time
To Trip
Resistance
Agency
Approvals
Current
(A)
Time
(Sec.)
R
min
(Ω)
R
typ
(Ω)
R
1max
(Ω)
2016L030 LF030 0.30 0.60 60 20 1.40 1.5 3.0 0.500 1.40 2.30
XX
2016L050 LF050 0.55 1.10 60 20 1.40 2.5 5.0 0.200 0.70 1.00
XX
2016L075/60 LF075-60 0.75 1.50 60 20 1.40 8.0 0.5 0.130 0.50 0.90
**
2016L100 LF100 1.10 2.20 15 40 1.40 8.0 0.5 0.100 0.25 0.40
XX
2016L100/33 LF100-33 1.10 2.20 33 40 1.40 8.0 0.5 0.100 0.25 0.40
XX
2016L150 LF150 1.50 3.00 15 40 1.40 8.0 1.0 0.070 0.13 0.18
XX
2016L200 LF200 2.00 4.20 6 40 1.40 8.0 3.0 0.048 0.07 0.10
XX
I
hold
= Hold current: maximum current device will pass without tripping in 20°C still air.
I
trip
= Trip current: minimum current at which the device will trip in 20°C still air.
V
max
= Maximum voltage device can withstand without damage at rated current (I max)
I
max
= Maximum fault current device can withstand without damage at rated voltage (V
max
)
P
d
= Power dissipated from device when in the tripped state at 20°C still air.
R
min
= Minimum resistance of device in initial (un-soldered) state.
R
typ
= Typical resistance of device in initial (un-soldered) state.
R
1max
= Maximum resistance of device at 20°C measured one hour after tripping or reflow soldering of 260°C for 20 sec.
Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.
* Agency Approval is Pending
Description
Features
Applications
t3P)4DPNQMJBOUMFBEGSFF
and halogen-free
t
'BTUSFTQPOTFUPGBVMU
currents
t)JHIWPMUBHF
t-PXQSPmMF
t*&&QPSUQSPUFDUJPO
t1PXFSFEFUIFSOFUQPSU
QSPUFDUJPO*&&&BG
t"VUPNPUJWFFMFDUSPOJD
control module protection
t-PXWPMUBHFUFMFDPN
equipment protection
Agency Approvals
AGENCY AGENCY FILE NUMBER
E183209
R50119118
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - 2016L Series

45Revised: March 19, 2012POLY-FUSE® Resettable PTCs© 2012 Littelfuse, Inc2016L SeriesSurface Mount > 2016L Series2016L SeriesSpecifications are subj

Page 2

46Revised: March 19, 2012POLY-FUSE® Resettable PTCs© 2012 Littelfuse, Inc.Surface Mount > 2016L Series2016L SeriesSpecifications are subject to chan

Page 3

47Revised: March 19, 2012POLY-FUSE® Resettable PTCs© 2012 Littelfuse, Inc2016L SeriesSurface Mount > 2016L Series2016L SeriesSpecifications are subj

Page 4 - 2016 L xxx /xx D R

48Revised: March 19, 2012POLY-FUSE® Resettable PTCs© 2012 Littelfuse, Inc.Surface Mount > 2016L Series2016L SeriesSpecifications are subject to chan

Page 5

49Revised: March 19, 2012POLY-FUSE® Resettable PTCs© 2012 Littelfuse, Inc2016L SeriesSurface Mount > 2016L Series2016L SeriesSpecifications are subj

Comments to this Manuals